IMMOBILINE DRYSTRIP PH 3-10NL
产品名称: IMMOBILINE DRYSTRIP PH 3-10NL
英文名称: IMMOBILINE DRYSTRIP PH 3-10NL
产品编号: 17-6001-12
产品价格: 0
产品产地: 美国
品牌商标: GE
更新时间: null
使用范围: null
- 联系人 :
- 地址 : 上海市宝山区友谊路1506号东智广场1109室
- 邮编 : 201900
- 所在区域 : 上海
- 电话 : 138****5983 点击查看
- 传真 : 点击查看
- 邮箱 : 342786402@qq.com
17-6000-86 | IPG-BUFFER, PH 4-7L |
17-6000-87 | IPG-BUFFER, PH 3-10L |
17-6000-88 | IPG-BUFFER, PH 3-10NL |
17-6001-10 | IMMOBILINE DRYSTRIP PH 4-7,7CM |
17-6001-11 | IMMOBILINE DRYSTRIP PH3-10,7CM |
17-6001-12 | IMMOBILINE DRYSTRIP PH 3-10NL, |
17-6001-13 | IMMOBILINE DRYSTRIP PH4-7, 13C |
17-6001-14 | IMMOBILINE DRYSTRIPPH3-10,13CM |
17-6001-15 | IMMOBILINE DRYSTRIP PH3-10NL, |
17-6001-78 | IPG BUFFER, PH 6-11 |
17-6001-88 | IMMOBILINE DRYSTRIP PH 6-9,18C |
17-6001-94 | IMMOBILINE DRYSTRIP PH 6-11,7C |
17-6001-95 | IMMOBILINE DRYSTRIP PH 6-11,11 |
17-6001-96 | IMMOBILINE DRYSTRIP PH 6-11,13 |
17-6001-97 | IMMOBILINE DRYSTRIP PH 6-11,18 |
17-6002-02 | IPG BUFFER, PH 3-5.6 NL |
17-6002-04 | IPG BUFFER, PH 4.5-5.5 |
17-6002-05 | IPG BUFFER, PH 5.0-6.0 |
17-6002-06 | IPG BUFFER, PH 5.3-6.5 |
Immobiline™ DryStrip Gels
- Immobiline™ DryStrip gels (IPG strips) are used for isoelectric focusing (IEF), run as the first dimension of 2-D electrophoresis or as a separate application.
- Immobiline™ DryStrip gels have been improved on several levels, through new process parameters, to produce first and second dimension gels of overall higher quality.
- Improved Immobiline™ DryStrip gels provide increased stability, reproducibility, and protein spot definition.
- Better spot definition improves spot quantitation in data analysis.
- Wide selection of IPG strips, pH gradients, lengths, and buffers for greater versatility.
- Immobiline™ DryStrip gels with matching IPG Buffer gives a high sample loading capacity and improves resolution.
Immobiline™ DryStrip Gels
Technical Information
Immobiline™ DryStrip pH 4-7 run according to standard procedures.
A) Spots are elongated in the second dimension due to skewed bands in the first dimension.
B) Improved Immobiline™ DryStrip gels provide a more stable pH gradient and better spot definition in the second dimension.
Immobiline™ DryStrip gels (IPG strips) are used for isoelectric focusing (IEF), run as the first dimension of 2-D electrophoresis or as a separate application. IPG strips contain a preformed pH gradient immobilized in precast polyacrylamide gels on a plastic backing. A comprehensive range of overlapping IPG strips covering narrow, medium, and wide pH ranges are available in various strip lengths, and the strips are individually packaged and bar coded for convenient handling and sample tracking.
Immobiline™ DryStrip pH 3-11 NL covers most proteins found in prokaryotic and eukaryotic cells, while the narrow-range strips can be used when higher resolution is required. The pH gradients at the extreme ends of the pH scale are nonlinear (NL) to distribute the proteins evenly over the gel length and obtain maximal resolution.
Immobiline™ DryStrip gels are rehydrated with a matching IPG Buffer prior to use. Samples can be included directly in the rehydration solution for efficient loading of dilute samples or for loading larger amounts of protein. Samples can also be loaded after rehydration. The first dimension separation is carried out using Ettan™ IPGphor™ 3 IEF system or Multiphor™ II flatbed system. When used for 2-D DIGE applications, the gels give accurate and reliable 2-D results.
TECHNICAL SPECIFICATIONS | |
Gel dimensions | 70 × 3 × 0.5 mm, 110 × 3 × 0.5 mm, 130 × 3 × 0.5 mm, 180 × 3 × 0.5 mm, 240 × 3 × 0.5 mm |
Gel matrix | Polyacrylamide T = 4%, C = 3% |
Gel backing | Polyester film |
Storage | -20° C |
Shelf life | 18 months |
SELECTION GUIDE - Immobiline™ DryStrip Gels and IPG Buffers
Guidelines for choosing Immobiline DryStrip gels
- Use shorter strips for fast screening or when only the most abundant proteins are of interest.
- Use longer strips for maximal resolution and loading capacity.
- To overview total protein distribution, use pH 3-11 NL strips.
- For increased resolution between pH 5-7, use a nonlinear gradient pH 3-10 strip to distribute the proteins more evenly over the strip.
- Combine pH 3-7 NL and pH 6-11, pH 3-7 NL and pH 6-9, or select from 3-5.6 NL, 5.3-6.5, 6.2-7.5, and 7-11 NL when more detail is required.
- Use narrow pH range strips (1 pH unit) to closely study proteins in the regions of interest.
http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=164456